| MIL-C-60872A
Gage
202
Case damaged
Visual
203
Varnish inadequate or missing
Visual
4.6.2 Delay Element, M69, Drawing 10551589, covering a detail of Drawing 10551590.
Critical
1
Mixed delay elements
Visual
2
Flash hole missing or obstructed
Visual
3
Primer uncrimped or seal missing
Visual
4
Marking missing, incorrect, or illegible
Visual
5
Delay charge not visible through flash hole
Visual
6
Metal defective
9
|