| ![]() MIL-C-62207B(AR)
4.6.3.4 Low temperature. Use item 7 of table VI or suitable equipment
and subject the assembly to the low temperature test specified in MIL-STD-810,
method 502.1, procedure I, The storage temperature shall be -65F. The
lowest operating temperature shall be -25F. The performance tests of table
III shall be applied.
4.6.3.5 Temperature cycling. With power and loads of table I applied,
subject the assembly to the temperature profile specified in figure 2. At the
conclusion of this test, subject the assembly to the performance tests of
table III.