| ![]() MIL-C-64025(AR)
3.4
Environmental conditions.
The electronics assembly shall
3.4.1 Transportation vibration.
show no evidence of internal or external damage that will affect the
intended functions following Transportation Vibration Test No. 119,
Procedure 2 of MIL-STD-331.
The Remote Control Unit shall perform
3.4.2 Temperature range.
as required herein and in Drawing 933026 over the temperature range,
after one (1) hour conditioning at temperature.
Cold -35 (+0/-5) degrees F
a.
Hot +145 (+5) degrees F
b.
Ambient 70 (+10/-10) degrees F
c.
Shock. The electronic assembly shall perform as required
3.4.3
after impact environments that provide mechanical shock of TBD G's
peak wit a duration of TBD ms minimum, TBD ms maximum.
3.5 Soldering. All soldered electrical connections shall comply
with MIL-S-46844, and MIL-S-45743.
Electronic assembly parts that are to be
Solderability
3.5.1
soldered shall comply with the solderability
requirements
of
MIL-S-45743 or as otherwise specified.
This
Remote Control Unit Performance characteristics .
3.6
describes the performance characteristics of the Remote
section
Control Unit (RCU), assembly number 9332873.
3.6.1 RCU power off current. With the voltage at Pi-RED
(+14.4 VDC) with respect to P1-BLK (COMMON ) set to 13 + 0.5
volts (Nominal Battery Voltage), the unit power Switch off, the
current flowing into Pi-RED shall be 2.0 milliamperes maximum when
tested per 4.5.2.1
RCU standbv current . With the voltage (Pi-RED with
3.6.2
respect to P1-BLK) set to 13 + 0.5 volts, the unit power switch on
and displays blank, the current flowing into PI-RED shall be 100
milliamperes maximum when tested per 4.5.2.2
3.6.3 Keyboard lights. All the keyboard keys shall be backlit
when the unit power switch is on when tested per 4.5.2.3