| QUALITY CONFORMANCE INSPECTION
CLASSIFICATION OF DEFECTS & TESTS
MIL-C-64025(AR)
TITLE
PARAGRAPH
DRAWING NUMBER
Microcircuit, Digital
l OF 2
4.4.2.34
9332994
SHEET
Amplifier
NEXT HIGHER ASSEMBLY
9332962
NO. OF
AQL
EXAMINATION OR TEST
CATEGORY
SAMPLE
OR
REQUIREMENT
PARAGRAPH REFERENCE
100%
UNITS
PARAGRAPH
/lNSPECTION METHOD
None defined
Critical
Major
101
High temperature storage
100%
MIL-STD-883, Method
1008, Test Condition
C/Certification
102
Temperature cycling
100%
MIL-STD-883, Method
1010, Test condition
C/Certification
103
100%
Constant acceleration
MIL-STD-883, Method
2001, Test Condition
E,Y1 Orientation
Only/Certification
100%
104
Burn-in Test
MIL-STD-883, Method
1015, 160 hrs. @ 1.25
C Min./Certification
105
100%
Seal- Fine and Gross Leak
MIL-STD-883, Method
1014, Test Condition
A or B followed by C/
Certification
|