| MIL-C-64030(AR)
SIGNAL
FROM
TO
MCD1
J1-1
E53
MCD2
J1-14
E54
L1
E55
E25
L2
E56
E26
DET1
J1-12
E1
J1-13
DET2
E2
VHV
E7
E10
VBT
E9
J1-2
GND
E14
E20, J1-10, J1-23, J1-15
E14
GND
J1-24, J1-25, E40, E52
4.5.2.2.2 Test connections. Unless otherwise specified
herein, all test connections, adjustments and manipulations
specified for a test shall be retained throughout subsequent tests.
4.5.2.2.2.1 Loads.
Loads shall be connected as described
below.
LOAD
FROM
TO
1.5 ohm 2% 1W
DET1 (R) (J1-24)
DET1 (J1-12)
DET2 (J1-13)
1.5 ohm 2% 1W
DET2 (R) (J1-25)
See figure 6
TUBE1 (J1-16)
TUBE1 (R) (J1-3)
See figure 6
TUBE2 (R) (J1-4)
TUBE2 (J1-17)
TUBE3 (J1-18)
See figure 6
TUBE3 (R) (J1-5)
TUBE4 (J1-19)
See figure 6
TUBE4 (R) (J1-6)
See figure 6
TUBE5 (R) (J1-7)
TUBE5 (J1-20)
TUBE6 (J1-21)
See figure 6
TUBE6 (R) (J1-8)
TUBE7 (R) (J1-9)
See figure 6
TUBE7 (J1-22)
150 ohm 2% 2W
VBT (E9)
BTOK (E12)
150 ohm 2% 2W
CTOK (E16)
VBT (E9)
150 ohm 2% 2W
VBT (E9)
DALT (E15)
4400 uf 20% 30 v
CAP- (E20)
CAP+ (E7)
4.5.2.2.2.2 Power source. Set the output of a O to 15 volt
1A DC power source to 0 + 0.1 volt. Connect the negative terminal
to E14 (GND) and the positive terminal to E9 (VBT). Then set the
output voltage to 13 0.5 volts.
The inputs shall
4.5.2.2.2.3 Initial input conditions.
initially be connected as described below:
INPUT TERMINAL
CONNECTED TO
SIGNAL NAME
E10
VHV
0 0.2 volt
E41
DEP
0 0.2 volt
E42
DA
0 0.2 volt
E43
CLK
See 4.5.2.2.2.4
E44
ADATA
0 0.2 volt
E45
See 4.5.2.2.2.4
DLACK
Open
All Others
89
|