| MIL-C-70489(AR)
3.2.1.10
4.6.3.10
Data rate
10.
4.6.3.11
3.2.1.11
Built-in-Test (BIT)
11.
ESS and operating
12.
4.6.1
3.3.2 & 3.3.3
temperatures
3.3.4
4.6.2
ESS vibration
13.
AQL 1.0% Defective
MAJOR:
3.6
4.6.5
Workmanship
101.
4.4.2 Special samplinq.
4.4.2.1 Environmental special sample. Three MBC shall be
selected at random, as a special sample, from each lot or each 50
produced which ever occurs first.The sample shall meet the
requirements and tests in Table III.
TABLE III.
Classification of defects.
Test Procedure
Requirement
No.
Characteristics
4.6.4
3.3.5
Immersion
201.
4.4.2.2 Other special sample. One MBC shall be selected at
random, as a special sample, from each lot each 100 produced
which ever occurs first. The sample shall meet the requirements
and tests in Table IV.
TABLE IV.
Classification of defects.
Test Procedure
Requirement
No.
Characteristics
Applicable Drawing\
3.4
Fabrication
301.
Visual
Applicable Drawing\
3.7
302.
Materials
Visual
NOTE: The tests in Table IV shall be conducted at room ambient
temperature (as specified in 3.3.1).
4.4.3 Failure of sample. Should any one item of a special
sampling fail to meet the specified test requirements, acceptance
of the represented inspection lot will be suspended by the
Government until necessary corrections have been made by the
contractor and resubmitted items have been approved in accordance
with "Acceptance and Rejection" as specified in MIL-STD-105.
4.5 Inspection equipment. Except as otherwise provided for
by the contract, the contractor shall supply and maintain
inspection equipment in accordance with the applicable
requirements of MIL-I-45607.
7
|