| MIL-C-70724(AR)
6.4 Submission of test data. Distribution of records shall
be in accordance with the contract.
6.5 Hazard notice. The cartridge described herein and some
of its components are flammable and explosive and consequently
present hazards in manufacture, handling, storage and shipment.
The contractor should recognize these hazards and take appropriate
measures to prevent fires, explosions? adverse environment, rough
handling, corrosive atmosphere, and electrically induced
incidents. Such measures shall include the employment of an
effective safety program that addresses the inherent hazards
associated with the cartridge.
6.6 Drawings. Drawings listed in Section 2 of this
specification under the heading U.S. Army Armament Research
Development and Engineering Center (ARDEC) may also include
drawings prepared by, and identified as Edgewood Arsenal,
Frankford Arsenal, Rock Island Arsenal, U.S. Army Armament
Research and Development Command (ARRADCOM), U.S. Army Armament
Research and Development Center (ARDC), or Picatinny Arsenal
drawings. Technical data originally prepared by these activities
is now under the cognizance of ARDEC.
6.7
Subject term (key word) listing.
Small Caliber Training Ammunition
Small Caliber Armaments
Small Caliber Test Procedures
Trichloroethane
Definitions.
6.8
Number of Stoppages
Reliability = 1 -
Number of Rounds Fired
Degradation of reliability - For the purpose of this specification
the degradation of reliability of the cartridge is determined by
the following equation:
Reliability Degradation = Reliability (control) - Reliability
(test)