Click here to make tpub.com your Home Page

Page Title: Alternative quality conformance provisions.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
MIL-C-70725A (AR)
4.5.3.1, Continued - Notes:
Failure to comply with the applicable requirement shall be
cause for rejection of the lot subject to testing of a
second sample consisting of double the quantity used in the
first test.  Failure of the cartridges in the second sample
to comply with the applicable requirement shall be cause for
rejection of the lot.
Failure of two or more cartridges to comply with the
applicable requirement shall be cause for rejection of the
lot.  If one cartridge fails in the first test, a second
sample consisting of double the number of cartridges in the
first sample shall be tested.  If any failing cartridges are
found in the second sample, the lot shall be rejected.
Failure of three or more cartridges to comply with the
applicable requirement shall be cause for rejection of the
lot.  If one or two cartridges fail in the first test, a
second sample consisting of double the number of cartridges
in the first sample shall be tested.  The lot shall be
rejected if in the combined first and second sample, three
or more cartridges fail to comply with the applicable
requirement.
Failure of 16 or more cartridges to comply with the bubble
test requirement shall be cause for the rejection of the
lot.  If more than 11, but less than 16 cartridges fail in
the first test, a second sample consisting of double the
number of cartridges in the first sample shall be tested.
The lot shall be rejected if in the combined first and
second sample, 27 or more cartridges fail to comply with the
bubble test requirement.  The waterproof firing/velocity
test (3.4.1.4.2, 4.6.5) may be substituted for the bubble
test in the first test or the retest, using the same sample
sizes.
Failure of the cartridges in any sample to comply with the
applicable requirements, shall be cause for rejection of the
lot, subject to testing of a second sample consisting of
double the quantity of cartridges used in the first test,
for the temperature or temperatures at which the failure
occurred.  The lot shall be rejected if the cartridges in
the second sample fail to comply with the applicable
requirements.
Divided equally among two weapons.
Check for compliance with the requirement.
26

Privacy Statement - Press Release - Copyright Information. - Contact Us