| MIL-C-70726A (AR)
QUALITY CONFORMANCE INSPECTION
CLASSIFICATION OF DEFECTS AND TESTS
12576458
Cartridge, Caliber .50 Blank, XM928
4.5.2.1 (Cont.)
CONFORMANCE REQUIREMENT INSPECTION
EXAMINATION
REFERENCE
PARAGRAPH
CRITERIA
MINOR:
201. DISCOLORED, DIRTY, OILY, OR
VISUAL
LEVEL
VI
3.1
SMEARED (WATERPROOFING)
VISUAL
3.1
LEVEL
VI
202. DENTED CASE (5)
VISUAL
3.1
LEVEL
VI
203. DRAW SCRATCH IN CASE (8)
VISUAL
3.1
LEVEL
VI
204. SCRATCH IN CASE (9)
VISUAL
3.1
LEVEL
VI
205. SCALY METAL ON CASE (12)
206. FOLD, WRINKLE BUCKLE, OR BULGE
VISUAL
3.1
LEVEL VI
IN CASE (14, 15, 16, 17)
207. HEAD STAMP MISSING OR
VISUAL
3.1
LEVEL VI
ILLEGIBLE (18)
VISUAL
3.1
LEVEL VI
208. DEFECTIVE HEAD (19)
209. NO WATERPROOFING MATERIAL
(PRIMER POCKET JOINT) (37),
VISUAL
3.1
LEVEL VI
IF APPLICABLE
210. DEFECTIVE CRIMP (PRIMER (38)
VISUAL
3.1
LEVEL VI
IF APPLICABLE
VISUAL
3.1
LEVEL VI
211. WORKMANSHIP
Refer to visual defect standards in MIL-STD-636 for location
of defects indicated in parenthesis.
Regardless of location or occurrence of loss of propellant.
The contractor may have this inspection requirement waived
upon successful demonstration that a case 100% filled with
propellant does not constitute a safety hazard.
Requiring more than 355 N (80 lbf) to insert in profile and
alignment gage.
22
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |