| ![]() MIL-C-70726A (AR)
QUALITY CONFORMANCE INSPECTION
12576458
Cartridge, Caliber .50 Blank, XM928
4.5.3.1 (Cont.)
Failure of two or more cartridges to comply with the applicable
requirement shall be cause for rejection of the lot. If one
cartridge fails in the first test a second sample consisting of
double the number of cartridges in the first sample shall be
tested. If any additional cartridges fail in the second test the
lot shall be rejected.
Failure of nine or more cartridges to comply with the
applicable requirement shall be cause for rejection of the lot. If
more than four, but less than nine cartridges fail in the first
test, a second sample consisting of double the number of cartridges
in the first sample shall be tested. The lot shall be rejected if
in the combined first and second sample, nine-or more cartridges
fail to comply with the applicable requirement.
See Table VI.
The cyclic rate shall be measured during the function and
casualty test. Failure of any 100 round burst to comply with the
applicable requirement shall be cause for rejection of the lot,
subject to testing a second sample consisting of double the number
of cartridges in the first sample. Failure of any 100 round burst
in the second sample to comply with the applicable requirement
shall be cause for rejection of the lot. The second sample shall
be fired in the same weapon type in which the failure occurred.
These tests may be performed concurrently with function and
casualty testing.
25
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |