| MIL-C-70784 (AR)
Firinq defects
TABLE I.
Rej
Acc
Cartridge:
2
0
Misfire
1
0
Failure to chamber
1
0
Failure to extract
1
0
Projectile remaining inbore
1
0
Inbore sabot separation
Primer:
25
9
Primer leak
6
1
Primer perforation
1
0
Loose primer
1
0
Blown primer
Case:
Longitudinal
split
31
10
H or S
11
4
G or J
1
0
K, L or M
Circumferential
rupture,
partial
11
4
S, J or K
4
1
G or L
1
0
Circumferential rupture (complete)
1
0
Detached metal
Projectile:
Failure of the sabot, base, and nose
7
2
cover to separate
Metal parts separation - penetrator
7
2
and windscreen
See Figure 1 for classifying splits and ruptures in fired
If a longitudinal split or circumferential
cartridge cases.
rupture (partial) extends into two or more defined areas, only the
most severe defect criterion of Table I for the areas involved
shall apply. If a rupture results in separation of the cartridge
case into two or more portions. the defects shall be classified as
a complete circumferential rupture.