| MIL-D-23222A(AS)
PRELIMINARY MECHANICAL INSTABILITY TESTS. - Pre-
3.3.5.2.7
liminary mechanical instability tests, the scope
of which is defined in the Contract Design Data Requirements, shall
have been performed and the data reported to NAVAIR.
ARMAMENT
3.3.5.2.8
STRUCTURAL SAFETY. - The helicopter contractor
3.3.5.2.8.1
shall perform such ground tests and flight tests
as are deemed safe by the contractor within the established flight
envelope to to demonstrate the structural safety and adequacy of installa-
tion of all armament and associated equipment (Paragraph 3.11). The
armament and associated equipment shall include, as applicable, guns,
rockets, droppable stores, missiles, mounts, attachments, release
equipment, control equipment, and bombing/navigation system. Simu-
lated shapes of correct weight shall be used if service type equipment
specified is not available.
FUNCTIONAL TESTs l - The helicopter contractor shall
3.3.502.8.2
perform functional tests to the extent that suit-
able operational equipment is available to demonstrate safe and proper
operation of the equipment tested. Ground functional tests shall
include firing of guns, missiles, and rockets as applicable; arming
and rearming; fit testing; release of all droppable stores (normal
and emergency release); adequacy of safety devices; adequacy of
handling equipment; adequacy of installation clearances; evaluation
armament control items within the cockpit; and the operation of
bombing/navigation system. Flight functional tests shall include
further evaluation of armament control items within the cockpit;
tests of release and control system; firing of guns, missiles and
rockets as applicable; normal and emergency release of applicable
stores; and the operation of bombing/navigation system.
PHOTOGRAPHIC
3.3.5.2.9
STRUCTURAL SAFETY. - The helicopter contractor
3.3.5 .2.9.1
shall perform, as applicable, such ground tests
and flight tests as are deemed safe by the contractor within the
established flight envelope, to determine the structural safety and
adequacy of titillations of all photographic and associated equipment
(para. 3.16). The photographic and associated equipment shall include,
as applicable, cameras, mounts, camera doors and windows, viewfinders,
control equipment, spare photographic equipment, and pyrotechic
illuminants. Simulated shapes of correct weight shall be used if
service type equipment specified is not available.