| MIL-D-50837(MU)
4.3.2.1 Classification of characteristics. Critical,
major and minor characteristics are defined in MIL-STD-105.
Inspection shall be conducted as follows:
4.3.2.1.1 Disc, solid, plain (see dwg. 8787112) and
disc, solid, plain, training (see dwg 8787200).
Categories
Characteristics
Method of Inspection
None defined
Critical:
Major:
101. Parallelism of left face (see dwg. 8787112) . . . . . . .Gage
102. Chamfer present (see dwg. 8787112) . . . . . . . . . . . . . Visual
103. Diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Gage
104. Thickness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Gage
105. Material (see 3.1) . . . . . . . . . . . . . . . . . . . . . . Visual
106. Objective evidence (see 6.2) for protective
finish In accordance with dwg. 8787112 . . . . . . . . . . . Visual
Minor :
201. Surface finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Visual
202. Stamping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Visual
203. Serialization (see S. S) . . . . . . . . . . . . . . . . . . . . . . . Visual
204. Workmanship (see 3. 4) . . . . . . . . . . . . . . . . . . . . . .Visual\Manual
4.3.2.1.2 Preparation for delivery (see 5,1).
Method of Inspection
Characteristics
Categories
Critical:
None defined
Major:
101. Preservation, packaging, packing and marking
in accordance with MIL-STD-1169 (MU) . . . . . . Visual/Manual
Minor:
201. Workmanship (see 3.4). . . . . . . . . . . . . . . .
Visual\Manual
4.3.2.1.3 Bag, packing for repair parts (see dwg. 8883534
covering part number 883534-4 and 5.2)
Method of Inspection
Characteristics
Categories
Critical:
None defined
Major:
101. Material (see 3.1) . . . . . . . . . . . . . . . . . . . . .Visual
102. Length before packing, min . . . . . . . . . . . . . . . . .*Measure
103. Width before packing, min. . . . . . . . . . . . .*Measure
5
|