MIL-D-52916A(ME)
3.18 Noise limits. The noise produced by the distributor shall conform with MIL-STD-1474
requirements, with the exception of MIL-STD-1474, 5.2, 5.3 and 5.4, when tested in accordance
with 4.5.2.7. The provision of MIL-STD-1474, 4.3 and 4.4, shall be provided if and only if
MIL-STD-1474, 5.1.1.2 procedures have been pursued and documented to the satisfaction of the
procuring activity and written permission to exceed the 85 dB(A) limit is obtained from the
procuring activity. Hazard signs shall conform with MIL-STD-1474, 4.3, except the sign will
state "HEARING PROTECTION REQUIRED WITHIN (specify) FEET". The sign shall be
readable at a distance indicated on the sign.
3.19 Safety. All rotating or reciprocating parts and other parts subject to high operational
temperatures that are of such a nature or are located to be or be a hazard to the operating or
attending personnel, shall be substantially guarded or installed to the extent necessary to
eliminate the hazard. External equipment including catwalks, handrails, fenders and bumpers
will be designed for durability and operator safety. All catwalks shall be provided with antiskid
surfacing. All platform steps and handholds shall be of such design to permit unhampered and
nonhazardous access to and from the distributor.
3.20 Electrical system. The distributor shall be equipped with a waterproof, 24-volt
vehicular electrical system for service and blackout night travel. All components and wiring
shall be located and guarded to prevent damage and permanent deformation, and to provide
maximum protection from shock and vibration. The components and wiring shall be accessible
for replacement without disturbing permanently installed housings and guards. The electrical
system shall be in accordance with table I. Item quantities, that are not specified shall be
furnished as required (AR) for each distributor.
TABLE I. Electrical system.
Description
Requirement
Quantity
Service lamps: Clearance,
MS35423
14 ea., min.
side-marker, and identi-
fication
Blackout lamps: Clearance
MS35424
8 ea.
and sidemarker
Installation
Horizontal, using
AR
information on MS35422
Service turn signal lamps,
Commercial, SAE I
2 ea
front
(SAE J759), pedestal
mount, waterproof
Service combination lamps,
Commercial, SAE STI
2 ea.
rear
(SAE J759), recess
or flush mount,
waterproof
11