| ![]() MIL-D-70603 (AR)
4.4
Quality Conformance Inspection.
4. 4.1 Inspe ct ion lot format ion.
Inspection lots shall comply
with the lot formation provisions of MIL-A-48078.
In addition,
each inspection lot shall contain:
a. Metal parts assemblies of one lot inter fix number from
one manufacturer .
b. Primers of one lot inter fix number from one
(See 4.4.5)
manufacturer .
c. Lead azide of one lot interfix number from one
manufacturer .
RDX of one lot interfix number from one manufacturer.
d.
4.4.2 Examination.
See MIL-A-48078.
a. Sampling plans. Unless otherwise specified in the
Classification of Defects and Test Tables, sampling plans and
procedures for major and minor defects shall be in accordance with
MIL-STD-105, Inspection Level II. Continuous sampling plans in
accordance with MIL-STD-1235 may be used if approved by the
procuring activity.
|