| MIL-D-70789A (AR)
3.5.4
Electrical
interface.
3.5.4.1 Connectors. Connectors shall conform to
MIL-C-38999. Each external connector reference designation, part
number, number of contacts, contact size, purpose of connector,
and mating connector is defined in Table I. DRU signal connector
J1 pin functions shall be in accordance with Table II. Termina-
tions shall be as shown in Figure 4.
3.5.4.1.1 Shield groundinq. Connecting cable external and
internal shields will be grounded directly to the connector
backshells. J1, J2 and J3 connector shells shall provide a path
to the DRU chassis of less than 2.5 milliohms resistance from DC
to 10 MHz.
TABLE I.
PRU connector information.
Mates
Number Contact Connector
Connector
Connector
with
Size
Purpose
of
Part Number
Reference
Contacts
Designator
(Chassis Corm)
MS27467T19F35P
Signal
MS27468T19F35S
66
22D
J1
MS27467T15F15S
Power
20
14
MS27468T15F15P
J2
16
1
J3*
22D
MS27467T19F35PB
Test
66
MS27468T19F35SB
MS27467T21F35PA
Test
22D
MS27468T21F35SA
79
*Contractor may select either listed connector for J3.
22
|