MIL-D-70789A (AR)
3.7.10 Shock.
3.7.10.1  Operational (Gunfire). The DRU shall not be
damaged and shall operate during and after repeated gun firing
shock in the M109 Self Propelled Howitzer as described in the two
TECOM Reports No. 86-LR(V)-41, Firing Test of M109E4 Howitzer.
respectively.  The  DRU  is  trunnion  mounted  in  the  M109
application. Inquiries concerning the M109 mounting DETAILS./
should be directed to the procuring activity. Figures 12 through
14 were extracted from the referenced reports and provide an
example of the shock spectra for the highest level charge (M203)
fired in the M109.