| MIL-D-70789A (AR)
APPENDIX C
******************************************************************
TRANSPORT MODE COMPLETE
30.3.19
Command:
DRU
Prime
System
To:
From:
This command allows the operator to terminate the
Function:
current Air or Marine Transport Mode and return the DRU to its
mode of operation prior to transport.
DRU Response:
STATUS DATA Message. When the DRU is not in
either the Air Transport or Marine Transport mode, the DRU shall
set ALERT DATA bit D5/6 (Invalid Mode Request)
COMMAND STRUCTURE
ERROR DET. CODE
DATA
COMMAND
SEQUENCE
FLAG ( F )
CHARACTERS(E)
NUMBER(N)
CHARACTERS(D)
CODE ( C )
FLAG ( F )
01111110
16 Bits
XXX
10100
D1
01111110
Number of Data Characters: 1
Unsigned Binary
Data Format:
Command Subcode
D1 Character (8 bits)
Value:
18