MIL-D-81347C(AS)
Explosion Proofing N o t r e q u i r e d .
-
3.3.10.4
3.3. 10.5
Temperature - The equipment shall operate as specified herein
from -25C to and including +55C. The equipment shall also operate as specified for tests above
+55C per MIL-T-5422 except for the Drum Auxiliary Memory Subunit (DAMS) of Logic Unit 4 which
shall not be required to meet the DAMS error rate requirements. However, no damage or degrada-
tion shall occur to the DAMS during high temperature MIL-T-5422 tests. From below -25C to -54C
the equipment shall not be required to meet specification performance requirements; however, no
damage or degradation shall occur to the equipment within the -25C to -54C limits.
Altitude - The equipment shall operate satisfactorily up to a
3.3.10.6
maximum altitude of 15,000 feet.
Warm-Up Time - The time required for the equipment to warm
3.3.11
up prior to operation shall be kept to a minimum and shall not exceed 0.5 minutes from 0 to and in-
eluding +55C and 5 minutes from less than 0C to and including -25 `C.
Power
3.3.12
Primary Input Power Requirements - The equipment shall meet
3.3.12.1
all applicable requirements of MIL-STD-704 and shall give specified performance from the following
power sources with characteristics as defined in MIL-STD-704 having limits as modified herein. The
equipment shall operate within the bounds of limits 2 and 3 of Figure 3 of MIL-STD-704 except that the
lower limit of curve 3 shall not fall below 80 volts. Operational malfunction may occur when the input
voltage exceeds the above limits but remains within limits 1 and 4 of Figure 3 of MIL-STD-704. How-
ever, no damage shall be suffered by the equipment under transient conditions defined herein. Normal
operation shall autoctmatically be resumed upon return of the input voltage to levels within limits 2 and 3
as modified herein. The power required shall not exceed the following specified amounts.
(1) AC Power (Three-Phase) 115/200 V, Category B
588
VA
Logic Unit 1
609
VA
Logic Unit 2
609
VA
Logic Unit 3
810
VA
Logic Unit 4
24
VA
Universal Keyset
24
VA
Pilot's Keyset
---
Ordnance Panel
Armament/Ordnance
78 VA
Test Panel
(2) AC Power (Single Phase) 115 V, Category B
30.5 VA
Logic Unit 1
30.5 VA
Logic Unit 2
30.5 VA
Logic" Unit 3
30.5 VA
Logic Unit 4
77 VA
Universal Keyset (es)
50 VA
Pilot's Keyset
22 VA
Ordnance Panel
Armament/Ordnance
----
Test Panel
AC Power - The equipment shall operate on an input voltage
3.3.12.1.1
of 115 volts, line to neutral, 200 volts line to line, three phase 400 Hz as described in MIL-STD-704
Category B mode of operation except as modified herein.
9