Page Title: Master Timing Logic
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
MIL-D-81347C(AS)
3.5.3.4.4
Master Timing Logic
Functional Description - The Master Timing Logic (MTL) shall
3.5.3.4.4.1
provide the timing and control signals necessary to "line-lock" (sync) display operations to the air-
craft's 400 Hz power source. It shall also provide diagnostic control for Logic Unit 3.
Figure 127 is a functional flow diagram of the MTL.
3.5.3.4.4.2
Interface Requirements
3.5.3.4.4.2.1
General
Signa1 S to Master Timing Logic - The MTL shall receive sig-
3.5.3.4.4.2.1..1
nals shown in Figure 127 from both the MPD 1 Logic, MPD 2 Logic, the PDL, the FGL, the power
supply, the MCP and the computer.
Signals from MPD 1 Logic - The signals received from the MPD
3.5.3.4.4.2.1.1.1
1 Logic shall be as follows:
(1) Radar Scan Converter Enable - When this signal is present,
the MTL shall transmit the RADAR S. C. Enable signal to both the Radar Scan Converter and MPD 1
Logic, and the RADAR Unblank to MPD 1.
(2) Spare Scan Converter Enable - When this signal is present,
the MTL shall transmit the SPARE S. C. Enable signal to both the Spare Scan Converter and MPD 1
Logic.
(3) LLLTV Active - When this signal is a logic "1", the MTL
shall cause the sync pulse to be generated at a 57.1 HZ rate. When this Signal is a logic "0", the
MTL shall cause the sync pulse to be generated at a 40 Hz rate.
(4) Diagnostic Data - When so instructed MPDL 1 shall trans-
mit 24 bits of diagnostic data and a diagnostic sync to the MTL.
Signals from MPD 2 Logic - The signals received from the MPD
3.5.3.4.4.2.1.1.2
2 Logic shall be as follows:
(1) Radar Scan Converter Enable - When this signal is present,
the MTL shall transmit the RADAR S.C.  Enable signal to both the Radar Scan Converter and MPD 2
Logic, and the Radar Unblank to MPD 2.
(2) Spare Scan Converter Enable - When this signal is present,
the MTL shall transmit the SPARE S. C.  Enable signal to both the Spare Scan Converter and MPD 2
Logic.
(3) LLLTV Active - When this signal is a logical "l", the MTL
shall cause the Sync pulse to be generated at a 57. 1 Hz rate. When this signal is a logical "O", the
MTL shall cause-the `sync pulse to be, generated at a 40 Hz rate.
Diagnostic Data - When so instructed the MPDL 2 shall
transmit 24 bits of diagnostic data and a diagnostic sync to the MTL.
Signals from Power Supply - The MTL shall receive from the
3.5.3.4.4.2.1.1.3
power supply a 400 Hz 10% sine wave which is synchronized to the aircraft primary power source.
Signals from Function Generator Logic - When instructed the
3.5.3.4.4.2.1.1.4
FGL shall transmit 12 bits of diagnostic data and a diagnostic sync to the MTL.
Signals from Pilot Display Logic - When so instructed the PDL
3.5.3.4.4.2.1.1.5
shall transmit 12 bits of diagnostic data and a diagnostic sync to the MTL.