Click here to make tpub.com your Home Page

Page Title: Storage temperature
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
MIL-E-48441A(MU)
Elbow Assembly
F11733401
Calibration Instructions For
D11738130
Elbow Assembly
Boot, Objective
F11746721
Holder, .Eyepiece
F11746724
C11746729
Holder, Eyepiece 10" Collimator
D11746730
Eyepiece Assembly 10" Collimator
F11746736
Test Set-up for M35 Elbow Assembly
PACKAGING DATA SHEET
Packaging of Elbow Assembly, Passive
PS11733401
11733401
(copies of specifications, standards, drawings and packaging data sheet
required by suppliers in connection with specific procurement functions
should be obtained from the procuring activity or as directed by the
contracting officer.)
3. REQUIREMENTS
3.1 Fabrication. - The elbow assembly shall be manufactured in
accordance with Drawing F11733401 and drawings pertaining thereto,
3.2 Interchangeability. - The elbow assembly shall be capable of
insertion into and removal from Periscope: M32E1, 35E1 and M36E1 (gages
are specified in lieu of periscopes in 4.6.10).
3.3 General specifications. - The contractor shall be responsible
for adherence to, and compliance with the following requirements of MIL-
F-13926,
a.
Order of precedence
b.
Dimensions and tolerance
c.
Inorganic protective surface finishes
d.
Part identification and marking
e.
Workmanship
3.4 Environmental.
3.4.1 Storage temperature. - The elbow assembly shall show no
evidence of cement separation, glass breakage or other physical failure,
and shall meet all the requirements of this specification at standard
ambient temperature (plus 60 to plus 90F) after having been exposed
and thermally stabilized at ambient- temperatures of minus 80 and plus
160F.
3.4.2 Operating temperatures. - The elbow assembly shall meet the
applicable requirements of 3.5 while exposed and thermally stabilized at
temperatures of minus 40F and plus 150F.
3.5 Operability.-