MIL-E-48630(AR)
See MIL-A-48078.  The first article sample
4.3.3 Rejection.
shall be rejected if any part, sub-assembly or assembly fails to
comply with any of the examinations or tests specified in this
specification or any of the requirements of the applicable
drawings.  In addition, the first article samples shall be rejected
if the ballistic test sample fails as described below:
P/N 9342551-1 & -2
a.  Any one (1) electronic assembly functions in any mode
after expiration of the self-destruct time out (Hazardous dud).
b.  Five (5) or more electronic assemblies function prior
to the minimum self-destruct time or prior to being subjected to a
valid target signature (early).
c.  A total of three (3) or more electronic assemblies fail
to function when subjected to a valid target signature.
d.  A total of four (4) or more electronic assemblies fail
to function in any mode (Non-hazardous dud).
P/N 9342552-1 & -2
a.  Any one (1) electronic assembly functions in any mode
after expiration of the self-destruct time out (Hazardous dud).
b.  Five (5) or more electronic assemblies function prior
to the minimum self-destruct time or prior to being subjected to a
valid target signature (early).
c.  A total of three (3) or more electronic assemblies fail
to function when subjected to a valid target signature.
d.  A total of four (4) or more electronic assemblies fail
to function in any mode (Non-hazardous dud).