| ![]() 3.3.2 Environmental
3.3.2.1 Storage temperature. The assembly shall meet the require-
ments of 3.3.1 at ambient temperature after exposure to and thermal
stabilization at -80 F and -1600F.
3.3.2.2 Operating temperatures. The assembly shall meet the
requirements of 3.3.1 while exposed to and thermally stabilized at -40F
and +125F, subsequent to which the requirements of 3.3.1 shall be met at
ambient temperature.
3.3.2.3 Vibration. The assembly shall show no physical failure
and shall meet requirements of 3.3.1 after being exposed to the
following vibratory conditions:
1/64 inch, constant
a. Amplitude:
(1/32 inch double amplitude
Simple harmonic
b. Vibratory motion:
5 to 55 to 5 Hertz in a 5-minute period
c. Sweep time:
Three linear or logarithmic sweeps
d. Vibration cycling:
applied to each of the three mutually
perpendicular axes.
6
|