| ![]() MIL-E-50738(MU)
8 August 1973
4.5.1 Government furnished inspection equipment. Where the
contract provides for Government furnished inspection equipment, supply
and maintenance of inspection equipment shall be in accordance with the
applicable requirements specified in MIL-I-45607.
4.5.2 Contractor furnished inspection equipment.
4.5.2.1 Government design. Unless otherwise specified in the con-
tract, all inspection equipment specified by drawing number in specifications
or SQAPS forming a part of the contract shall be supplied by the contractor
in accordance with applicable technical data listed in the TDP.
4.5.2.2 Contractor design. The contractor shall design and supply
inspection equipment compatible with the test methods and procedures speci-
fied in 4. 6 of this specification and with the component inspection procedures
specified in examination and test facilities provisions of MIL-F-13926. Since
tolerance of inspection equipment is normally considered to be within 10 per-
cent of the product tolerance for which intended, this inherent error in the
inspection equipment design must be considered as part of the prescribed
product tolerance limit. Thus, concept, construction, materials, dimen-
sions, and tolerances used in the design of inspection equipment shall be so
selected and controlled as to insure that the inspection equipment will reliably
indicate acceptability of a product which does not exceed 90 percent of the
prescribed tolerance limitt and permit positive rejection when nonconforming.
Construction shall be such as to facilitate routine calibration of inspection
equipment.
4.6 Test methods and procedures
4.6.1 Test conditions. Unless otherwise specified, the test
conditions shall be in accordance with the test facilities provisions
of MI MIL-F-13926.
4.6.1.1 Initial conditions. Apply the loads to the assembly as
specified in table I.
4. 6.2 Battery power relay drive test. Apply the power source of
table I (item 2.1 to F1-11. Measure the voltage at P1-13 tc determine
compliance with 3.3.1.1. Connect P1-20 to P1-7. Measure the voltage
at P1-13 to determine compliance with 3.3.1.1. Apply the power source
of table I to P1-11, P1-22 and P1-21. Conect P1-20 to P1-7. Measure
the output at P1-13 to determine compliance with 3.3.1.1.
10
|