MIL-E-7104D(WEP)
* 3.6.5.2
Form Factor - The envelope dimensions of the magazine shall not exceed 20
inches long by 9 inches wide by 33 inches high.
3.7
Rounds - The equipment shall operate with the following rounds which shall not
be supplied as part of the equipment.
Weight (pounds)
Round
Size (inches)_
2.920 0. 025D by 18.50 0. 045L
3.25
MK 7 Mod 2 Marine Marker
2.970 0.010D by 18.45 0.098L
MK 25 Mod O Marine Marker
4
4. QUALITY ASSURANCE PROVISIONS
* 4.1
General - The inspection and testing of equipment covered by this specification
shall be performed in accordance with the quality assurance provisions of Specification MIL-L-22769,
unless otherwise specified herein.
* 4.2
Design Approval Tests do not apply.
* 4.3
P-reproduction Tests - Preproduction tests are required only when procurement
is made from a source which has not previously furnished equipment in accordance with this specifi-
cation. Preproduction tests shall consist of:
(1) Unasterisked tests listed in Table II of Specification MIL-L-22769.
(2) Interference tests in accordance with Specification MIL-I-6181.
(3) Proof and burst pressure tests in accordance with Specification
MIL-P-5518.
(4) Acceleration testing in accordance with Specification MIL-E-5272,
Procedure X, so that the magnitude and direction of the resultant
loads derived in accordance with Specification MIL-A-8591 are
applied to the equipment.
5. PREPARATION FOR DELIVERY
5.1
General - All major units and parts of the equipment shall be preserved,
packaged, packed and marked for the level of shipment specified in the contract or order in accord-
ance with Specification MIL-P-7936.
6.
NOTES
*6.1
Test Values - Normal and limiting values of performance data shall be deter-
mined at input voltages of 27.5 O.5 V DC and 115 1.0 V AC, and pneumatic pressures of 3000
50 PSIG. These data are to be used in testing the equipment at installations points for compliance
th minimum acceptable standard of performance.
6.2
Precedence of Documents - When the requirements of the contract, this specifi-
cation, or applicable subsidiary specifications are in conflict, the following precedence shall apply
(1) Contract - The contract shall have precedence over any specification.
(2) This specification - This specification shall have precedence over all
applicable subsidiary specifications. Any deviation from this specifi-
cation, Or from subsidiary specification where applicable, shall be
specifically approved in writing by the procuring activity.