Click here to make tpub.com your Home Page

Page Title: J.T Clearance
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
MIL-F-14252 (AR)
repaired in a normal manner.
Serviced or
1.l  J.T  Clearance - Clearance between wires or harnesses,
and Parts such as electrical tubes  resistors,  and dyamot ors,
J
Shall  be Sufficient to avoid deterioration of the wires because
(if' the heat. dissipated by such parts under service conditions.
C1earance between any two electrical circuits or between any
elect rical circuit and ground shall be such as to meet the re-
quirements for dielectric strength (see 3.11.23) and insulation
resistance,`see 3.11.22) ., For bare minimum assurance of opera t-
ing stability in wired equipment, the minimum separating dis-
tances for potential points shall be as shown in Table XII
These  values are based on the point spark gap breakdown volt-
ages under extreme probable operative conditions of high tem-
perature and high altitude.
Table XII
[capacitive effects.- Wires and harnesses
leSS used as a design feature of the equipment, shall be the mini-
mum practicable
3.11.14.9  splicing.- Wires in a continuous run between two ter-
spliced during assembly of the equipment,
minals shall Not
except where a stranded conductor is spliced to a solid conductor
and the two are supported at the splice.
3.11.14.10
Insulating sleevling. - Insulating sleeving shall not
be used when ot her means of insulation are practicable.
37

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business