| MIL-F-15733/24C
Moisture resistance: In accordance with MIL-PRF-15733 except after the 24 hour drying period, insulation
resistance shall not be less than 50 Megohms.
Life: In accordance with MIL-PRF-15733 and Method 108, MIL-STD-202, test condition D (1,000 hr) for qualification
inspection; test condition B (250 hrs) for group C inspection.
Part or Identifying Number (PIN): Consists of the basic number of this specification sheet and a dash number from
table I.
M15733/24
-0001
Basic document
Dash number
number
from table I
Supersession data: See table II.
TABLE II. Supersession data.
Inactive PIN
Superseding
Superseding
MIL-F-15733/24-
specification sheet
PIN
0001
MIL-PRF-28861/4
M28861/04-005TB
0002
MIL-PRF-28861/4
M28861/04-023TB
0003
MIL-PRF-28861/4
M28861/04-004TB
0004
MIL-PRF-28861/4
M28861/04-022TB
0005
MIL-PRF-15733/58
M15733/58-0001
0006
MIL-PRF-15733/58
M15733/58-0001
0007
MIL-PRF-15733/58
M15733/58-0002
0008
MIL-PRF-15733/58
M15733/58-0004
0009
MIL-PRF-28861/4
M28861/04-002TB
0010
MIL-PRF-28861/4
M28861/04-002TB
0011
MIL-PRF-28861/4
M28861/04-005TB
0012
MIL-PRF-28861/4
M28861/04-008TB
0013
MIL-PRF-28861/4
M28861/04-020TB
0014
MIL-PRF-28861/4
M28861/04-020TB
0015
MIL-PRF-28861/4
M28861/04-023TB
0016
MIL-PRF-28861/4
M28861/04-026TB
0017
MIL-PRF-28861/4
M28861/04-001TB
0018
MIL-PRF-28861/4
M28861/04-001TB
0019
MIL-PRF-28861/4
M28861/04-004TB
0020
MIL-PRF-28861/4
M28861/04-007TB
0021
MIL-PRF-28861/4
M28861/04-019TB
0022
MIL-PRF-28861/4
M28861/04-019TB
0023
MIL-PRF-28861/4
M28861/04-022TB
0024
MIL-PRF-28861/4
M28861/04-025TB
5
|