| ![]() MIL-F-20420J(AR)
4.4.3.1 Jumble test.
(See 3.4). The flare assemblies shall be
observed and examined visually without disassembly for evidence of
failure to comply with the requirements as classified in Table II.
TABLE II - Jumble Test Requirement
4.4.3.1.1 First three lots - Beginning with the first lot
produced and continuing until three (3) consecutive lots have
complied with the requirements fifty (50) flare assemblies shall be
selected from each lot for this test. The lot shall be rejected if
during the test a critical defect occurs or four (4) or more
assemblies exhibit the major defect listed in Table II. The test
procedure shall be as specified in 4.5.2.
4.4. 3.1.2 Reduced sampling after three lots - After three (3)
consecutive lots have compiled with the criteria of 4.4.3.1.1,
twenty (20) flare assemblies shall be selected from each lot for
test l The lot shall be rejected if a critical defect occurs or two
(2) or more assemblies exhibit the major defect listed in Table II.
The test procedure shall be as specified in 4.5.2.
4.4.2.2 Moisture or volatile content as applicable (see Table
Major defects.
TABLE III - Moisture or Volatile Content
40
|