| MIL-F-45598A
time required to attain the steady state rate is recorded. The
instrumentation shall also record the time delay (.150 .01s)
between the removal of the feeder solenoid voltage and the
removal of the drive motor voltage. There shall be a minimum of
nine rounds ejected through the clearing port of the feeder from
the time the feeder solenoid is de-energized and voltage is
removed from the drive motor, indicating proper clearing action
takes place.
4.5.4 Interchange of parts.
In plant.
4.5.4.1
4.5.4.1.1 Feeders. Feeders shall be tested for interchange
of parts (see 3.4.18) by disassembling and then reassembling
parts using the parts and pre-arranged system specified below.
Interchange of parts shall be accomplished by dividing the parts
of each feeder into three groups of non-mating parts as shown
below and distributing the groups into three different trays
until each tray contains parts for a complete feeders. Groups of
parts from the first feeder shall be taken in order and placed in
trays 1 through 3; groups of parts from the second feeder shall
be taken in order and placed in trays 2, 3, and 1; groups of
parts from the third feeder shall be taken in order and placed in
trays 3, 1, and 2. Commercial parts such as screws, spring pins,
etc., shall be placed in the same tray as their mating or
associate part. Any commercial part rendered unserviceable by
disassembly shall be replaced without penalty to the
interchangeability test. The feeders shall be reassembled using
only those parts which are in the same tray.