MIL-F-46375A(MU)
Examination and tests .-  (Components and subassemblies shall
4.2.2
be inspected in accordance with the inspection provisions contained in
MIL-F-13926 and the Supplementary Quality Assurance Provisions (SQAP) listed
in the List of Inspection Documents$ IEL 8614051. Examinations and tests
-
related to Section 3 herein shall be performed on a defect (individual
characteristic) basis in accordance with the "Classification of Defects"
as specified in Table I below$ and the inspection level and sampling plans
specified in MIL-STD-105.  Examinations and tests for packaging, packing
and marking shall be in accordance with MIL-P-14232 and Section 5 herein.
The tabulated classification of defects shall constitute the minimum in-
spection to be performed by the supplier prior to Government acceptance
or rejection by lot.  The Government reserves the right to inspect for
any applicable requirement, and to reject individual non-conforming items.
TABLE I - (CLASSIFICATION OF DEFECTS
Use Inspection Level II of Table I with
Sampling Plan Table II-A of MIL-STD-105
TEST PROCEDURES
CRITICAL: NONE
REQUIREMENTS
MAJOR: AQL 1.0 percent defective
101.
Physical failure post vibration
3.3.3
4.5.3
102.
Performance failure post vibration
3.3.3
4.5.3
3.4.1.1
Running torque exceeds required
103.
4.5.4.1
force
3.4.1.2
104.
Adapter fails to lock in place or
4.5.4.1
remain secure in lock position
Socket difficult to remove or insert
105.
or remain free f-rem shake or wobble
3.4.2
4.5.4.2
3.4.3.1
4.5.4.3
106.
Instrument light switch requires ex-
cess force to function
3.4.3.1
4.5.4.3
107.
Instrument light switch fails to
function properly when the re-
quired force is applied and then
released
3.4.3.2
4.5.4.4
Instrument lamp flickers or fails to
108.
light when switch button is depressed
Lack of continuity
3.4.4
109.
4.5.4.5
MINOR: NONE DEFINED
Disposition of non-conforming product.- Rejected lots shall
4.2.3
be screened for all defective characteristics. Removal or correction of
defective units and resubmittance of rejected lots shall be in accordance
with "Acceptance and Rejection" as specified in MIL-STD-105.
4.3
Special samplinq.
General.-  One fuze setter shall be selected at random by a
4.3.1
Government representative as a sample from each 100 produced, or from each
months production whichever occurs first.  The sample shall meet the re-