| MIL-F-48057B (AR)
AMENDMENT 7
4.4.2.27: Major 101, Delete "(a)"; delete "4.5.11.3" and
substitute "4.5.11.2.1 or 4.5.11.2.2".
Add "Major 103 Release pin improperly assembled (Type II
Only) 100% 3.2
Visual".
PAGE 47
*
4.4.2.27, Delete in its entirety and substitute included Page 9
(Page 47)
PAGE 48
4.4.2.29: Delete Major 101 in its entirety.
Major 102:
Delete
"14.5.12.2" and substitute "4.5.12.2".
PAGE 49
In No. of Sample Units, Delete "15" and substitute
4.4.2.30:
"30".
PAGE 50
Delete "11008392" and substitute "8883718" in two
4.4.2.31:
places.
*
Add new paragraph "4.4.2.32" included page 10 (page 50A).
PAGE 51
4.4.4.1.1: Delete "S&A position check" and substitute "Non-
Arming Test".
4.4.4.1.2:
Delete "4.5.10".
PAGE 52
4.4.4.2: Under VERIFIED INSPECTION, Delete "4.5.10 - S&A Position
Check" and substitute "4.5.11.2 - Non-Arming Test".
PAGE 53
4.5.4: Change paragraph "c" to paragraph "d" and add new
paragraph "c" as follows:
"c. A Power Supply and a simulated detonator load (2 to 5
ohms) are required to perform the capacitor discharge test."
4.5.5.1: Delete "Apply a" and substitute "Apply the required".
Delete "resistive" and substitute "required".