| MIL-F-48267 (PA)
3.8 Burn-In. - The IC shall be burned-in at a temperature
of one hundred and twenty five degrees centigrade plus or minus
five degrees centigrade (125C 5C) for a minimum time of one
hundred and sixty eight (168) hours using the test equipment of
4.4.5.
3.9 Group A Final Static Ambient Electrical Parameters. -
The IC shall meet the requirements of Table No. 2 when it is
tested at a temperature of twenty five degrees centigrade plus
or minus five degrees centigrade (25C 5C) using the test equip-
ment of 4.4.6.
3.10 Group A Final High Temperature Static Electrical Para-
meters. - The IC shall meet the requirements of Table No. 3 when
it is tested at a temperature of one hundred and twenty five de-
grees centigrade plus or minus five degrees centigrade (125C
5C) using the equipment of 4.4.7.
12
|