| MIL-F-48673 (AR)
LAMP TEST'. When depressed, lights the TEST RESULTS
display to all `8's", and illuminates all Mode Switches.
depressed lights the POWER
POWER switch. When
f.
power to the FCC under test through the FCC POWER
i n d i c a t o r t applies
connector~ and applies power to the test set.
Input
Provide +28
VDC
overcurrent
Circuit breakers.
9"
protection to the Test Set and the FCC.
Time totalizinq meter. Indicates accumulated operating
h.
time of the Test Set.
3.2.3.3 Test cable. The test cable connects the test set to
the FCC test connector.
3.2.3.4 FCC 1/0 wrap-around cable. This cable connects the FCC
digital output to FCC digital inputs and FCC analog outputs to FCC
analog inputs for test stimulation.
3.2.3.5 Power input cable. This cable connects +28 VDC input
power from the test facility to the Test Set.
o
3.2.3.6 FCC power cable. This cable connects switched +28 VDC
power from the Test Set to the FCC power input connector.
3.2.3.7 Self-test wrap- around cable. This cable connects the
Test Set self-test connector to the FCC test and FCC 1/0 connectors
on the Test Set.
.
3.2.3.8 Instruction manual. This manual contains operator
instructions~ test sequence (including self-test), and TEST RESULTS
s
display codes and explanations.
3.2.4 Major component list. The major components of the Test
Set are as follows:
Case, Combination
Panel Assembly
W Cable Assembly (Test)
W2 Cable Assembly (Pwr In)
W3 Cable Assembly (FcC Pwr )
W4 Cable Assembly (FCC 1/0)
W5 Cable Assembly (w/A)
Logic Assembly
Bezel Assembly, Display
400 Hz Ocillator Assmbly
Substructure Assembly
Component Board, Power Control
7
|