MIL-F-48673 (AR)
Test equipm e nt
TABLE XIX.
Suqgested Equipment
MinimUm Use Specifications
Nomenclature
Power Designs 3650S
Range: +13.5 to +16.5 VDC
D.C. Power Supplies
(2 required)
at 1 amp, output isolated
(2 required)
from power ground; -13.5
to -16.5 VDC at 1 amp,
output isolated from power
ground
Accuracy: Set with DMM
Fluke 8600A
DC:
DMM
Range : +4.9 to +16.5 VDC
Accuracy: 0.5 percent
AC:
Ran ge: 9.9 to 10.1 VAC
Accuracy: 0.25 percent
Fluke 1900A
Range: 388 to 412 Hz
Electronic Counter
Accuracy: 1 percent
Phipps and Bird 236A
10 Kohms at 10 ma
Range:
Decade Resistor
1 percent
Accuracy:
40.2
PRELIMINARY
PROCEDURE
40.2.1 Step 1. Visually inspect FCC-FTS for any physical
defects. If any are noted, corrective action shall be taken before
continuing calibration.
Carefully remove test set panel from carrying
40.2.2 Step 2.
case .
Connect test set power cord to test set J4
40.2.3 Step
connector and to an appropriate 28 VDC, 10 amp source
Verify that POWER indicator is extinguished.
If not, depress t e extinguish.
61