| MIL-F-50253A (AR)
4.4
Quality Conformance Inspection.
4.4.1 Inspection Lot Formation.
a.
One metal parts lot from one manufacturer,
b. RDX from not more than one lot or homogeneous blend
of lots, dwg. 8883684,
c. Explosive Composition A5 from not more than one lot
or homogeneous blend of lots, dwg. 8883685.
4.4.2 Examination.- Unless otherwise specified in the
Classification of Defects and Test Tables, sampling plans for
major and minor defects shall be in accordance with MIL-STD-105,
Normal Inspection Level II.