| MIL-F-50532A(MI)
criteria specified herein regardless of the type of sampling procedure
which is being applied to determine conformance with requirements. Lot
numbering, as required, shall be in accordance with MIL-STD-1168. Each
inspection lot shall contain:
a. Parts from not more than one interfix lot number from one
manufacturer.
b.
Lead azide of the same type from not more than two lots produced
by the same manufacturer in accordance with the same specification and same
specification revision and which have subsequently been subjected to
uniformly controlled drying and operating conditions at the loading
plant.
PETN from not more than one lot.
c.
Primers from not more than one interfix lot number from one
d.
manufacturer.
4.3.2 Examination. The examinations listed in the following sub-
paragraphs shall be performed on inspection lots (see 4.3.1) of the com-
ponents or assemblies designated in the applicable paragraph headings.
Inspection for critical defects (and major defects, when so specified)
shall be 100 percent. Sampling plans for major and minor defects shall be
in accordance with MIL-STD-105 except that continuous sampling plans in
accordance with MIL-STD-1235 may be used if approved by the Government.
Instead of applying the AQL's designated herein to the groups of major and
minor defects listed, the contractor may elect to apply AQL's to individual
defects using a AQL of 0.40 percent for each major defect and an AQL of
0.65 percent for each minor defect. When this method is elected, it shall
be applied to all of the major and minor defects listed in the applicable
subparagraph of this section, except where 100 percent inspection is
specified, and be documented as part of the contractor's inspection
system,
Equipment necessary for the performance of the inspections
listed shall be in accordance with 4.3.4.
8
|