| MIL-F-50994 (MU)
Location of stud holes and
103.
12003
rotor housing arm slot . . . . . . . . Gage
12004
Chamfer at base missing . . . . . . . Visual
104.
AQL 0.65 percent
Minor:
201.
Evidence of poor workmanship
12005
(see 3.5) . . . . . . . . . . . . . . . . . . . Visual
4.3.2.13 Rotor Housing Assembly (see dwg. 8883719 for a
detail of dwg. 9271602).
Code No.
Method of
Defects
Categories
Inspection
None defined.
Critical:
AQL 0.40 percent
Major:
13001
Arm width (nearest studs), min. Gage
101.
102.
Location of studs and nearest
13002
arm . . . . . . . . . . . . . . . Gage
AQL 1.00 percent
Minor:
Surface finish on arm in-
201.
13003
correct (nearest studs) . . . . . Visual
202.
Evidence of poor workmanship
13004
(see 3.5) . . . . . . . . . . . . . Visual
4.3.2.14 Device, Safety and Arming (see dwg. 9215619-1
covering a detail of dwg. 9271602).
Method of
Code No.
Categories
Defects
Inspection
Critical:
100 percent
1. Distance between annular gear
14001
and No. 2 gear, max. . . . . . . . . Gage
Major:
AQL 0.40 percent
101.
Alignment of detonator cavity
with the outside diameter ac-
14002
ross the rotor housing posts . . Gage
Minor:
AQL 0.65 percent
201.
Evidence of poor workmanship
14003
(see 3.5) . . . . . . . . . . . . . Visual
19
|