| MIL-F-51208(MU)
4.4
Sampling.
Sampling shall be
4 . 4 . 1 For examination and nondestructive tests.
conducted in accordance with Ml L- ST D-l 05. Samples for air resistance and
DOP penetration shalI be selected from items unit packaged.
4.4.2 For destructive tests. Sampling shalI be conducted in accordance
with
MIL-STD-105,
level
S-3.
4.5 Inspection provisions.
4 . 5 . 1 Examination and nondestructive tests. Sample filter element and
ring assemblies shalI be examined and tested in accordance with the classifica-
t i o n of defects and MIL-STD-105.
4 . 5 . 2 For destructive tests. Sample filter element and ring assemblies
shall be tested in accordance with 4.6.3. The acceptance number is zero.
4.5.3 Classification of defects.
4 . 5 . 3 . 1 Filter element and ring assembly (Dwg D5-3-892).
Acceptance standards
Defects
Categories
None defined
Critical:
A Q L 1.0 percent defective
Major:
Component incorrectly assembled
101
Component missing
102
OveralI diameter incorrect
103
O v e r a l l height incorrect
104
W o r k m a n s h i p (3.7)
105
A Q L 0.25 percent defective
Major A:
4.6.1
Air resistance
150
4.6.2
DOP penetration
151
A Q L 2.5 percent defective
Minor:
Height outside fold incorrect
201
5
|