| MIL-F-81966(AS)
TABLE 3. (CONT'D)
FINAL ASSEMBLY, POWER SUPPLY PP6419/AWW-4(V) (DWG. 125AS1OOO)
B.
CRITICAL - None
MAJOR - AQL 1.0 cumulative for all parameters
Use thread sealing compound as specified (Ref. Dwg. 125AS1OOO)
101.
Route wire bundles as specified (Ref. Dwg. 125AS1OOO)
102.
Install washers and sleeving as specified (Ref. Dwg. 125AS1OOO)
103.
104.
Wiring and soldering materials and procedures must be as specified
(Ref. Dwg. 125AS1OOO]
Wire lacing must be as specified (Ref. Dwg. 125AS1OOO)
105.
Application of compound to heat sink must be as specified
106.
(Ref. Dwg. 125AS1OOO)
Dimensions and weight must be as specified (Ref. Dwg. 125AS104)
107.
Wiring must be as specified (Ref. Dwg. 125AS102)
108.
Power transformer must be as specified (Ref. Dwg. 125AS112)
109.
Power supply inductor must be as specified (Ref. Dwg. 125AS122) ,
110.
Wiring, soldering and sleeving of relay assembly must be as specified
111.
{Ref. Dwg. 125AS123)
Identification plate dimensions and requirements must be as specified
112.
(Ref. Dwg. 12SAS124)
Ground cable assembly must be as specified (Ref. Dwg. 125AS127)
113.
FINAL ASSEMBLY, CONTROL C-8441 and C-8442/AWW-4(V) (DWG. 126AS1OO)
c.
CRITICAL - None
MAJOR -
AQL 1.0 percent cumulative for all parameters
Wiring and soldering of electrical connections must be as specified
101.
(Ref. Dwg. 126AS1OO)
Lacing, sleeving and varnish must be as specified (Ref. Dwg. 126AS1OO)
102.
Black oxide coating application must be as specified (Ref. Dwg. 126AS1OO)
103.
Panel lighting for all applications must be as specified
104.
(Ref. Dwg. 126AS1OO)
Lock washers to be as specified (Ref. Dwg. 126AS1OO)
105.
27
|