MIL-G-24477(SHIPS)
(b)
Distant reading temperature indicators:
(1) Lubricating oil from engine.
(2) Fresh water from engine.
(c)
Temperature indicators shall be furnished by
lation by the installing activity for the fo
(1) Sea water to and from heat exchanger.
(2) Fresh water to lubricating oil cooler.
(3) Fresh water to the engine.
(4) Lubricating oil to engine.
.
(d)
Alarms :
(1) Low lubricating oil pressure.
(2) High temperature cooling water.
(e)
Electrical temperature pyrometer and selector switch:
(1) Each cylinder exhaust outlet.
(f)
Tachometer:
(1) Engine speed.
(g)
Time indicator or hour meter:
(1) Engine operating time.
3.2.5.9.1 Panal. An instruction panal contained all instructments listed in 3.2.5.9(a),
(b), (c), (f), (g) and 3.3.9 shall be furnished with each engine designed for mounting on
the engine, off of but adjacent to the engine or located at the engine control stand. Panal
mounted instruments shall be flush mounted and 3-1/2 or 4-1/2 dial size and shall be shock
resistant  design.  All  duplex  gages  shall  be  4-1/2  inch  size.  Instruments
for reading from operating station and for maintenance and calibration checks. Instruments
shall be accordance with and installed inaccordance with table I as applicable: