MIL-c-48438 A(MU)
APPENDIX B
SWITCH
INDICATION
STEP
FIRE 1/FIRE 2 indicators out
Depress RESET
25
X over F1/F2 and FLIGT ENDED
Depress X over F1/F2 and
26
indicators light, AZ and EL digital
FLIGHT  ENDED
indicators display "88".
Fl ERROR/F2 ERROR indicator should
Depress F1 ERROR/F2 ERROR
27
light alternately - one always on. .
(depress
twice)
AZIMUTH ERROR indicator indicates 49
28
Position AZIMUTH cross
hair on TRACKING ERROR
meter to left or right
extreme of the reticle
ELEVATION ERROR indicate: indicates 49.
29
Position ELEVATION cross
hair on TRACKING ERROR
meter to maximum high or
low extreme
READY TO FIRE and FIRE 1 indicators
a. Position AZIMUTH and
30
light, AZIMUTH and ELEVATION ERROR
ELEVATION cross hairs on
indicators read less than "1O".
TRACKING ERROR meter to
center of reticle, place
F1 ERROR on.
b. . Depress MANUAL MODE
.
and FIRE 1
c. Position AZIMUTH and
ELEVATION cross hairs on
TRACKING ERROR meter to.
maximum extreme outside
of reticle
FIRE 2 indicator lights
d. Depress MANUAL MODE and
FIRE 2
e. Depress F2 ERROR
AZIMUTH and ELEVATION ERROR indicators
read 49.
Depress RESET
RESET indicator lights, resets console.
31
Depress BORESIGHT twice
Lights in BORESIGHT MODE out in
32
OPERATE MODE.