| ![]() MIL-G-82455(OS)
Table III
Shock Schedule
3.4.3 Acceleration .- The Generator shall be capable of with-
standing an acceleration of 35 g's in the aft direction and 25 g's in the
forward direction with the Generator in the ready condition (see 6.3).
3.4.4 Temperature.-
3.4.4.1
Operating.- The Generator shall meet the requirements
of 3.3 at any temperature from O to 140 degrees Fahrenheit (F).
3.4.4.2
Not operating.-
The Generator shall meet the performance
requirements and product characteristics after storage at any temperature
from
to
upon stabilization at any temperature specified in
3.4.4.1.
3.4.5
Humidity.- The Generator shall withstand exposure to
95 percent relative humidity at 110F for eight hours without degradation
of finish or functional capabilities.
3.4.6 Altitude.- The Generator shall meet the performance require-
ments of 3.3 subsequent to exposure to atmospheric pressure at any altitude
from O to 20,000 feet.
3.4.7 Attitude.- The Generator
requirements of 3.3 in any attitude.
3.5 Life.-
Storage life, ready nonoperating.- The Generator,
3.5.1
in service installation, shall have a storage life of one year.
7
|