MIL-G-85299(AS)
Electrical cage voltage limits.
TABLE VI.
(4) Missile audio, W1, P2-15.  The missile audio requirements shall be
as specified in 3.4.5.2.a.(10) except that the output shall be
disabled by an accept status of the electrical cage return thres-
hold detector in ACQA switch positions three and four. Disabled
output level shall be not greater than 0.1 volt ac, see
3.4.5.2.d(3).
(5) Electrical cage, W1, P2-30.  The output signal requirements shall
be the same as those for the Acquisition Lambda signal, as
specified in 3.4,5.2.d.(2), except that the output impedance shall
be 15K
15 percent ohms.
Requirements are as specified in
(6) Gas grain squib, W1, P2-13.
3.4.5.2.a.(7).
(7) Power changeover, W1, P2-19.
Requirements are as specified in
3.4.5.2.a.(8).
(8) Motor fire squib, W1, aft striker contact. Requirements are as
specified in 3.4.5.2.a. (9).
3.4.5.3 Pylon interface requirements.
a.
FUNCTION SELECT test one.
(1) 28 volt dc BUS, W1, P2-18 (W2, P2-15).
(a) A 7.87
5 percent ohms resistive load shall be applied
between ground and W1, P2-18 for 20 milliseconds out of each
second.
(b) The input pin shall be monitored for correct
voltage in
accordance with the accept/reject limits of
table IV. The
accept/reject decision shall be updated at a
one Hertz rate at
a point 14 milliseconds after application of
the 20
millisecond resistive load pulse.