| MIL-H-904J
c. For type H hoists, specify type of load chain and hoist capacity (fixed or invertible
capacity) (see 1.2.2)
d. Issue of DODISS to be cited in the Solicitation, and if required, the specific issue of
individual documents referenced (see 2.1.1 and 22)
e. When first article inspection is required (see 3.1)
f. Hoist shock resistance (grade A or B) (see 3.3.1)
g. If hooks do not require swivel capability or safety device (see 3.3.5.1)
h. Special size or range of "I" beam flange sizes required of trolley wheels (see 3.3.7.1), if
other than shown for standard "T" beams in tables III, IV, and V
i. Specify track clamps, if required (see 3.3.7.5). Trolley hoists for U.S. Navy ships should
have track clamps
j. Radius of curved track if other than specified (see 3.3.7.6)
k. If chain container is required (see 3.3.8)
l. If a load limiting device is to be provided as a part of the hoist (see 3.3.10). (The periodic
150 percent of rated load dynamic load test cannot be accomplished with these devices
installed. This device should not be specified for hoists to be used on board U.S. Navy
ships.)
m. If required lift height is other than standard (see tables II through VII)
n. Painting method required (see 3.10)
o. When group C tests are required (see 4.5)
P. Level of preservation, packing, and marking required (see 5.1)
q. When fire-retardant material is not required (see 5.1.a.).
6.3 Consideration of data requirements. The following data requirements should be
considered when this specification is applied on a contract. The applicable Data Item Descriptions
(DID's) should be reviewed in conjunction with the specific acquisition to ensure that only
essential data are requested/provided and that the DID's are tailored to reflect the requirements
27
|