| MIL-I-46576A(OS)
202
Box damaged
Visual
203
Sealing strip broken or missing
Visual
204
Marking missing, incorrect, or illegible
Visual
205
Cut, damaged, or improperly sealed bag
Visual
4.2.2.7 Box, Ammunition, Packing, Drawing 8796542.
Critical
None defined
Major
None defined
Minor
201
Contents loose
Manual
202
Strapping missing, loose, broken, or improperly engaged
Visual/Manual
203
Contents of box exposed
Visual
204
Box damaged
Visual
205
Marking missing, incorrect, or illegible
Visual
206
Number of units incorrect
Visual
4.2.2.8 Box, Fiberboard (Outer), Alternative, Ammunition, Packing, Drawing 9216934.
Critical
None defined
Major
None defined
Minor
201
Contents loose
Manual/Visual
202
Carton broken or damaged
Visual
203
Number of units contained incorrect
Visual
204
Marking missing, incorrect, or illegible
Visual
205
Tape incomplete
Visual
4.2.3 Inspection testing. The following tests shall be performed in accordance with 4.3.
4.2.3.1 Breakaway torque. Each assembly shall be subjected to the breakaway torque test of the
threaded joint between the cap and the chamber. Failure of any assembly to comply with 3.3 shall be cause
for rejection of the assembly.
4.2.3.2 Residual magnetism. Each initiator shall be subjected to the test for excessive residual
magnetism as specified in 4.3.2. Failure of any initiator to comply with 3.4 shall be cause for rejection of the
initiator.
7
|