| MIL-I-51175(MU)
(Dwgs:
B5-19-1663,
wire,
ground;
4.5.2.2 Electrical system assemblies.
B 5 - 1 9 - 1 7 6 7 , cable assembly; B5-19-1768, cable assembly; C5-19-1757, circuit
breaker and switch.)
Acceptance standards
Defects
Categories
None defined
Critical:
A Q L 1.0 percent defective
Major:
101
Component missing, incorrectly located
or assembled
Hole missing or location incorrect
102
M a r k i n g incorrect
103
Workmanship
(3.3)
104
A Q L 0.65 percent defective
Major A:
4.6.1
Electrical
continuity
151
4.6.1
Switch or circuit breaker nonfunctioning
152
A Q L 2.5 percent defective
Minor:
P r o t e c t i v e finish missing
201
Marking
illegible
202
4.6
Tests.
The
4 . 6 . 1 E l e c t r i c a l c o n t i n u i t y a n d circuit breaker/switch functioning.
electrical continuity of the cables and functioning of the circuit breaker and
switch shall be determined using Edgewood Arsenal Test Lamp (Dwg B136-52-60).
P R E P A R A T I O N FOR DELlVERY (For repair parts packaging, see 6.3)
5.
The components of the instalIation kit shalI be
5.1 Cleaning and drying.
c l e a n e d and dried in conformance with Specification MlL-P-116. Cleaning
process C-1 and any of the drying processes listed therein shalI be used.
Levels shalI be as specified (see 6.2).
5.2 Preservation and packaging.
5
|