| MIL-I-60281A
None defined
Minor
201 Contents loose Manual
202 Box damaged Visual
203 Sealing strip broken or missing
Visual
204 Marking missing, incorrect, or illegible
Visual
205 Cut, damaged, or improperly sealed bag
Visual
4.2.2.6 Box, Ammunition, Packing, Drawing 8830993.
Critical
None defined
Major
None defined
Minor
201 Contents loose Manual
202 Strapping missing, loose, broken, or improperly engaged
Visual/manual
203 Contents of box exposed Visual
204 Box damaged Visual
205 Marking missing, incorrect, or illegible
Visual
206 Number of units incorrect Visual
4.2.2.7 Box, Fiberboard (Outer), Alternative, Ammunition, Packing, Drawing 9216932.
Critical
None defined
Major
None defined
Minor
201 Contents loose Manual/visual
202 Carton broken or damageVisual
d
203 Number of units contained incorrect
Visual
204 Marking missing, incorrect, or illegible
Visual
205 Tape incomplete
Visual
4.2.3 Inspection testing. The following tests shall be performed in accordance with 4.3.
4.2.3.1 Breakaway torque. Each assembly shall be subjected to the breakaway torque test of
the threaded joint between the cap and the chamber. Failure of any assembly to comply with 3.3
shall be cause for rejection of the assembly.