| MIL-J-7093A
(Weps)
or other devices should be employed during manufacturing operations involving
electric primers, detonators or squibs.
(f) Enforce, where necessary, the wearing of suitable safety
footwear, gloves, goggles, respirators and impregnated garments to protect
personnel against burns, poisoning and associated industrial hazards.
(g) Allow no fires or exposed eIectrical or other sparking
equipment, and little or no flammable material to be present in loading, handling
and storage spaces. Enforce proper "Match" and "No Smoking" rules.
(h) Enforce good housekeeping and maintain effective policing,
inspection and supervisory methods throughout the loading urea and surroundings.
Employ effective cleaning methods periodically to minimize the accumulation of
explosives or explosive dust and other contamination upon, and assure its removal
from floors, walls, ceilings, ledges, tables, benches, piping, and equipment of
the items loaded; also, clean up any spilled material immediately.
(i) Igniters and rocket motors shall be shipped and stored
separately.
(j) Electrical equipment used shall be of the explosive resistant
type.
17
|