| MIL-L-40064E
4.4.2 Examination. Samples selected in accordance with 4.4.1 shall be
examined for the major and minor defects specified in 4.5.1. AQL shall be
2.5 percent defective for major defects and 4.0 percent defective for minor
defects.
4.4.3 Tests. Samples selected in accordance with 4.4.1 shall be tested
as specified in 4.5.2.1, 4.5.2.2 and 4.5.2.3. Inspection level shall be
S-3 with AQL of 1.0 percent defective.
4.5 Inspection procedure.
4.5.1 Examination. The sample loading plate shall be examined as speci-
fied herein for the following defects:
Major
Requirement
Defect
Paragraph
Defect
No.
3.1
101.
Loading plates not as specified.
3.3
102.
Materials not as specified.
3.3.1
103.
Materials not resistant to corrosion and
deterioration, or treated to be resistant
to corrosion and deterioration for the
applicable storage and operating environments.
3.3.1.1
Dissimilar metals as defined in MIL-STD-889
104.
are not effectively insulated from each other.
3.3.1.2
Contractor does not have documentation
105.
available for identification of material,
material finishes, or treatment.
3.3.2
Used, rebuilt or remanufactured components,
106.
pieces, or parts incorporated in the
loading plate.
3.3.3
Castings not as specified.
107.
3.4
Construction not as specified.
108.
3.4.1
Structural design not as specified.
109.
3.4.2
Lifting devices not as specified.
110.
3.4*3
Handgrips not as specified.
111.
3.4.4
Safety curbing not as specified.
112.
3.4.5
Floor surface not as specified.
113.
3.4.6
Position lockstop not as specified.
114.
3.4.7
Retaining devices, type IX not as specified.
115.
3.6
Dimensions not as specified.
116.
3.9
Workmanship not as specified.
117.
3.9.1
Welding not as specified.
118.