| ![]() MIL-L-52906(ME)
Tests shall be conducted in accordance with Table II.
4.5.2 Tests.
4.5.2.1 Weight. The weight of the loader shall be measured with a
scale calibrated within the last 6 months to prove conformance to 3.2.1.1.
Nonconformance to 3.2.1.1 shall be cause for rejection.
4.5.2.2 Dump height. The dump height of the loader shall be measured
to prove conformance to 3.2.1.2. Nonconformance to 3.2.1.2 shall be
cause for rejection,
4.5.2.3 Reach. The reach of the loader shall be measured to prove
conformance to 3.2.1.3. Nonconformance to 3.2.1.3 shall be cause for
rejection.
4,.5.2.4 Tipping load. The tipping load of the loader shall be measured
to prove conformance to 3.8.1 and 3.8.2. Nonconformance to 3.8.1
and 3.8.2 shall be cause for rejection.
4.5.2.5 Lift capacity. The lift capacity of the loader shall be
measured to prove conformance to 3.8.3. Nonconformance to 3.8.3 shall
be cause for rejection.
4.5.2.6 Breakout force. The breakout force of the loader shall be measured
to prove conformance to 3.8.4. Nonconformance to 3.8.4 shall be cause
for rejection.
The raising time of the loader shall be
4.5.2.7 Raising time.
measured to prove conformance to 3.8.5. Nonconformance to 3.8.5 shall
be cause for rejection.
4.5.2.8 Travel speed. The travel speed of the loader shall be
measured to prove conformance to 3.8.6. Nonconformance to 3.8,6 shall
be cause for rejection.
4.5.2.9 Drawbar pull. The drawbar pull of the loader shall be
measured to prove conformance to 3.8.7. Nonconformance to 3.8.7
shall be cause for rejection.
4.5.2.10 Clearance circle. The curb clearance circle shall be measured
to prove conformance to 3.8.8. Nonconformance to 3.8.8 shall be
cause for rejection.
15
|